Causes of vacuum drop signs of vacuum pump condensers

2024-08-20

The vacuum pump will inevitably fail in use, and the failure is not terrible. As long as you find out the cause, you can solve the problem in a targeted manner. I will introduce the reasons that cause the vacuum pump condenser to drop the vacuum.

1. The circulating water pump works abnormally or trips, the opening degree of the disc valve of the circulating pump is reduced or fully closed, and the circulating water inlet and outlet valves of the condenser are closed by mistake.

2. The stainless steel tube of the condenser is dirty.

3. The vacuum pump is not working properly or tripped.

4. The vacuum destruction valve is accidentally opened or not closed tightly, the vacuum system pipeline and other equipment systems are damaged or leaked, and the vacuum system valve is leaking.

5. The steam supply pressure of the shaft seal is significantly reduced, and the water level and negative pressure of the shaft are abnormal.

6. The hot water level in the condenser of the vacuum pump is too high.

7. Leakage of small machine vacuum system.

8. The explosion-proof door of the low-pressure cylinder of the large and small vacuum pumps is broken.

Guangdong Guangye Electromechanical Equipment Engineering Technology Co., Ltd. is an enterprise that integrates agent sales and after-sales maintenance to provide customers with air compressors, vacuum pumps, nitrogen machines and post-processing equipment. Our company is an agent of Bola State of Atlas Group. The company keeps its credit, abides by contracts, guarantees product quality, and wins the trust of customers with its multi-variety operating characteristics and the principle of small profits but quick turnover.